Error CodeDescription
004001System input voltage is higher than workable range(>305 volt)
004002System input voltage (L1, L2 or L3) is lower than workable range (<170 volt)
004005Temperature of air inlet or input contactor is higher than workable range
004006Temperature of CCS combo charging plug is higher than workable range
004007Air filters need to be replaced
004008System fan error
004009System Init Failed
00400AEmergency button is pressed
00400DTemperature sensor of air inlet is broken
00400ETemperature sensor of input contactor is broken
00400FSPD trigger
004010Output fuse on CCS relay board is broken
004011Output fuse on CHAdeMO relay board is broken
004012Temperature sensor of CCS combo charging plug is broken
004013Temperature of air inlet is lower than workable range
004014Stop charging by RFID
004015The plug-in times of CCS charging plug is more than 10000 times